Table 3. Measured value and calculated value for Plant Mat No. 2
Temperature measurement | | Calculation value |
Time | Temperature T1 | Temperature T2 | Temperature T3 | Temperature T4 | → | Calorie (Watt) | High temperature (average) | Low temperature (average) | Temperature difference | Thermal conductivity |
10:29:41 | 119.7 | 119.9 | 43.0 | 42.5 | | 30.83 | 119.80 | 42.75 | 77.05 | 0.126 |
10:59:41 | 117.8 | 118.1 | 43.0 | 42.4 | | 30.83 | 117.95 | 42.7 | 75.25 | 0.129 |
11:22:11 | 115.3 | 115.5 | 43.1 | 42.5 | | 30.83 | 115.40 | 42.8 | 72.60 | 0.134 |
11:51:41 | 113.1 | 113.2 | 43.2 | 42.5 | | 30.83 | 113.15 | 42.85 | 70.30 | 0.138 |
12:21:41 | 112.8 | 113.1 | 43.2 | 42.4 | | 30.83 | 11295 | 42.80 | 70.15 | 0.138 |
12:31:41 | 112.2 | 112.6 | 43.1 | 42.4 | | 30.83 | 11240 | 42.75 | 69.65 | 0.139 |
12:41:41 | 112.1 | 113.1 | 43.1 | 42.6 | | 30.83 | 11260 | 42.85 | 69.75 | 0.139 |
12:51:41 | 113.1 | 112.7 | 43.1 | 42.4 | | 30.83 | 11290 | 42.75 | 70.15 | 0.138 |
13:01:11 | 112.8 | 112.8 | 43.0 | 42.6 | | 30.83 | 11280 | 42.80 | 70.00 | 0.139 |
13:11:41 | 112.9 | 112.6 | 43.0 | 42.5 | | 30.83 | 11275 | 42.75 | 70.00 | 0.139 |
13:21:41 | 112.7 | 112.2 | 43.0 | 42.5 | | 30.83 | 11245 | 42.75 | 69.70 | 0.139 |
13:23:41 | 112.7 | 112.4 | 43.1 | 42.5 | | 30.83 | 11255 | 42.80 | 69.75 | 0.139 |
13:25:41 | 112.3 | 112.9 | 43.0 | 42.6 | | 30.83 | 11260 | 42.80 | 69.80 | 0.139 |
13:28:41 | 112.2 | 112.3 | 43.1 | 42.5 | | 30.83 | 11225 | 42.80 | 69.45 | 0.139 |
13:30:41 | 112.4 | 112.5 | 43.2 | 42.5 | | 30.83 | 11245 | 42.85 | 69.60 | 0.149 |
13:32:41 | 112.9 | 113.0 | 43.2 | 42.6 | | 30.83 | 11295 | 42.90 | 70.05 | 0.139 |
13:34:41 | 112.3 | 112.5 | 43.2 | 42.4 | | 30.83 | 11240 | 42.80 | 69.60 | 0.139 |
13:35:11 | 112.6 | 112.1 | 43.1 | 42.5 | | 30.83 | 11235 | 42.80 | 69.55 | 0.139 |
13:37:41 | 112.8 | 112.5 | 43.0 | 42.5 | | 30.83 | 11265 | 42.75 | 69.90 | 0.139 |
13:38:41 | 112.1 | 112.7 | 43.0 | 42.6 | | 30.83 | 11240 | 42.80 | 69.60 | 0.139 |